Skip to main content
All CollectionsCertification, Codes, and StandardsEnergy Codes (US Domestic)
Seattle Energy Code Amendments to Washington Energy Code 2018
Seattle Energy Code Amendments to Washington Energy Code 2018
Patrick Chopson avatar
Written by Patrick Chopson
Updated over a year ago

The Washington State Building Code is comprised of national model codes adopted by reference and amended at the state level. The city of Seattle made amendments to the Washington State Energy Code 2018 which is known as The Seattle Energy Code 2018. According to the Seattle Energy Code 2018 section C406.8.1, the building types are divided into the following groups:

  1. Group R-1: Boarding houses, hotels, or motels.

  2. Group I-2: Hospitals, psychiatric hospitals, and nursing homes.

  3. Group A-2: Restaurants and banquet halls or buildings containing food preparation areas.

  4. Group F: Laundries.

  5. Group R-2: Buildings with residential occupancies. (Not applicable after 1/1/2022)

  6. Group A-3: Health clubs and spas.

Following are the few key amendments for prescriptive inputs used in cove.tool:

Cove.tool Assumptions (all engineering inputs can be easily edited by the user):

  1. Referring to the PNNL prototype models, the wood-framed walls with the attic roof are assumed for the small office building and steel-framed walls with insulation entirely above deck are assumed for all other commercial building types in cove.tool.

  2. The fixed metal framing windows are assumed for all building types.

  3. Window SHGC values are picked for the 'SEW' direction when the Projection Factor(PF) is less than 0.2.

Find out more about the Seattle Energy Code here.