Building System Electrification

lifecycle operational carbon, system electrification

Christopher Riddell avatar
Written by Christopher Riddell
Updated over a week ago

In the Carbon Feature, the building system selected in the Baseline Energy Model is expected to be electrified in the 18th year of operation. This table shows the baseline system and the electric replacement used in the lifetime operational carbon calculation. If the baseline system is already a primarily electric system, no change is made.

System Type Name

Primary Energy

Electrified system update at 18th year - decarbonization scenario

CAV w/ Radiant, with Gas Boiler and Packaged DX

Gas

CAV w/ Reheat, with ASHP and Packaged DX

CAV w/ Reheat, with Gas Boiler and Air Cooled Chiller

Gas

CAV w/ Reheat, with ASHP and Air Cooled Chiller

CAV w/ Reheat, with Gas Boiler and Packaged DX

Gas

CAV w/ Reheat, with ASHP and Packaged DX

CAV w/ Reheat, with Gas Boiler and Water Cooled Chiller

Gas

CAV w/ Reheat, with ASHP and Water Cooled Chiller

DOAS w/ FCU, with Gas Boiler and Air Cooled Chiller

Gas

DOAS w/ FCU, with ASHP and Air Cooled Chiller

DOAS w/ FCU, with Gas Boiler and Water Cooled Chiller

Gas

DOAS w/ FCU, with ASHP and Water Cooled Chiller

DOAS w/ Induction, with Gas Boiler and Air Cooled Chiller

Gas

DOAS w/ Induction, with ASHP and Air Cooled Chiller

DOAS w/ Induction, with Gas Boiler and Water Cooled Chiller

Gas

DOAS w/ Induction, with ASHP and Water Cooled Chiller

DOAS w/ Radiant, with Gas Boiler and Air Cooled Chiller

Gas

DOAS w/ Radiant, with ASHP and Air Cooled Chiller

DOAS w/ Radiant, with Gas Boiler and Water Cooled Chiller

Gas

DOAS w/ Radiant, with ASHP and Water Cooled Chiller

DOAS w/ VRF, with Gas Boiler and Cooling Tower

Gas

DOAS w/ VRF, with Electric Boiler and Cooling Tower

DOAS w/ WSHP, with Gas Boiler and Cooling Tower

Gas

DOAS w/ WSHP, with Electric Boiler and Cooling Tower

Natural Vent, with Gas Boiler and Direct Expansion

Gas

Natural Vent, with ASHP and Direct Expansion

Single Zone, with Furnace and Air Cooled Chiller

Gas

Single Zone, with Air Source Heat Pump

Single Zone, with Furnace and Direct Expansion

Gas

Single Zone, with Air Source Heat Pump

Single Zone, with Furnace and Packaged DX

Gas

Single Zone, with Air Source Heat Pump

Single Zone, with Furnace and Water Cooled Chiller

Gas

Single Zone, with Air Source Heat Pump

Single Zone, with Gas Boiler and Air Cooled Chiller

Gas

Single Zone, with Air Source Heat Pump

Single Zone, with Gas Boiler and Packaged DX

Gas

Single Zone, with Air Source Heat Pump

Single Zone, with Gas Boiler and Water Cooled Chiller

Gas

Single Zone, with Air Source Heat Pump

VAV w/ Radiant, with Gas Boiler and Water Cooled Chiller

Gas

VAV w/ Radiant, with ASHP and Water Cooled Chiller

VAV w/ Reheat, with Gas Boiler and Air Cooled Chiller

Gas

VAV w/ Reheat, with ASHP and Air Cooled Chiller

VAV w/ Reheat, with Gas Boiler and Packaged DX

Gas

VAV w/ Reheat, with ASHP and Packaged DX

VAV w/ Reheat, with Gas Boiler and Water Cooled Chiller

Gas

VAV w/ Reheat, with ASHP and Packaged DX

CAV w/ Radiant, with Electric Resistance and Packaged DX

Electric

CAV w/ Radiant, with Electric Resistance and Packaged DX

CAV w/ Reheat, with ASHP and Air Cooled Chiller

Electric

CAV w/ Reheat, with ASHP and Air Cooled Chiller

CAV w/ Reheat, with ASHP and Packaged DX

Electric

CAV w/ Reheat, with ASHP and Packaged DX

CAV w/ Reheat, with ASHP and Water Cooled Chiller

Electric

CAV w/ Reheat, with ASHP and Water Cooled Chiller

CAV w/ Reheat, with Electric Boiler and Air Cooled Chiller

Electric

CAV w/ Reheat, with Electric Boiler and Air Cooled Chiller

CAV w/ Reheat, with Electric Boiler and Packaged DX

Electric

CAV w/ Reheat, with Electric Boiler and Packaged DX

CAV w/ Reheat, with Electric Boiler and Water Cooled Chiller

Electric

CAV w/ Reheat, with Electric Boiler and Water Cooled Chiller

CAV w/ Reheat, with Electric Resistance and Air Cooled Chiller

Electric

CAV w/ Reheat, with Electric Resistance and Air Cooled Chiller

CAV w/ Reheat, with Electric Resistance and Packaged DX

Electric

CAV w/ Reheat, with Electric Resistance and Packaged DX

CAV w/ Reheat, with Electric Resistance and Water Cooled Chiller

Electric

CAV w/ Reheat, with Electric Resistance and Water Cooled Chiller

CAV w/ Reheat, with GSHP

Electric

CAV w/ Reheat, with GSHP

DOAS w/ FCU, with ASHP and Air Cooled Chiller

Electric

DOAS w/ FCU, with ASHP and Air Cooled Chiller

DOAS w/ FCU, with ASHP and Water Cooled Chiller

Electric

DOAS w/ FCU, with ASHP and Water Cooled Chiller

DOAS w/ FCU, with Electric Boiler and Air Cooled Chiller

Electric

DOAS w/ FCU, with Electric Boiler and Air Cooled Chiller

DOAS w/ FCU, with Electric Boiler and Water Cooled Chiller

Electric

DOAS w/ FCU, with Electric Boiler and Water Cooled Chiller

DOAS w/ FCU, with Electric Resistance and Air Cooled Chiller

Electric

DOAS w/ FCU, with Electric Resistance and Air Cooled Chiller

DOAS w/ FCU, with Electric Resistance and Water Cooled Chiller

Electric

DOAS w/ FCU, with Electric Resistance and Water Cooled Chiller

DOAS w/ FCU, with GSHP

Electric

DOAS w/ FCU, with GSHP

DOAS w/ Induction, with ASHP and Air Cooled Chiller

Electric

DOAS w/ Induction, with ASHP and Air Cooled Chiller

DOAS w/ Induction, with ASHP and Water Cooled Chiller

Electric

DOAS w/ Induction, with ASHP and Water Cooled Chiller

DOAS w/ Induction, with Electric Boiler and Air Cooled Chiller

Electric

DOAS w/ Induction, with Electric Boiler and Air Cooled Chiller

DOAS w/ Induction, with Electric Boiler and Water Cooled Chiller

Electric

DOAS w/ Induction, with Electric Boiler and Water Cooled Chiller

DOAS w/ Induction, with Electric Resistance and Air Cooled Chiller

Electric

DOAS w/ Induction, with Electric Resistance and Air Cooled Chiller

DOAS w/ Induction, with Electric Resistance and Water Cooled Chiller

Electric

DOAS w/ Induction, with Electric Resistance and Water Cooled Chiller

DOAS w/ Induction, with GSHP

Electric

DOAS w/ Induction, with GSHP

DOAS w/ Radiant, with ASHP and Air Cooled Chiller

Electric

DOAS w/ Radiant, with ASHP and Air Cooled Chiller

DOAS w/ Radiant, with ASHP and Water Cooled Chiller

Electric

DOAS w/ Radiant, with ASHP and Water Cooled Chiller

DOAS w/ Radiant, with Electric Boiler and Air Cooled Chiller

Electric

DOAS w/ Radiant, with Electric Boiler and Air Cooled Chiller

DOAS w/ Radiant, with Electric Boiler and Water Cooled Chiller

Electric

DOAS w/ Radiant, with Electric Boiler and Water Cooled Chiller

DOAS w/ Radiant, with Electric Resistance and Air Cooled Chiller

Electric

DOAS w/ Radiant, with Electric Resistance and Air Cooled Chiller

DOAS w/ Radiant, with Electric Resistance and Water Cooled Chiller

Electric

DOAS w/ Radiant, with Electric Resistance and Water Cooled Chiller

DOAS w/ Radiant, with GSHP

Electric

DOAS w/ Radiant, with GSHP

DOAS w/ VRF, with Electric Boiler and Cooling Tower

Electric

DOAS w/ VRF, with Electric Boiler and Cooling Tower

DOAS w/ VRF, with Ground Source

Electric

DOAS w/ VRF, with Ground Source

DOAS w/ WSHP, with Electric Boiler and Cooling Tower

Electric

DOAS w/ WSHP, with Electric Boiler and Cooling Tower

DOAS with VRF

Electric

DOAS with VRF

Natural Vent, ASHP and No Cooling

Electric

Natural Vent, ASHP and No Cooling

Natural Vent, with ASHP and Direct Expansion

Electric

Natural Vent, with ASHP and Direct Expansion

Natural Vent, with Electric Boiler and Direct Expansion

Electric

Natural Vent, with Electric Boiler and Direct Expansion

Natural Vent, with Electric Resistance and Direct Expansion

Electric

Natural Vent, with Electric Resistance and Direct Expansion

Single Zone, with Electric Boiler and Air Cooled Chiller

Electric

Single Zone, with Electric Boiler and Air Cooled Chiller

Single Zone, with Electric Boiler and Packaged DX

Electric

Single Zone, with Electric Boiler and Packaged DX

Single Zone, with Electric Boiler and Water Cooled Chiller

Electric

Single Zone, with Electric Boiler and Water Cooled Chiller

Single Zone, with Electric Resistance and Air Cooled Chiller

Electric

Single Zone, with Electric Resistance and Air Cooled Chiller

Single Zone, with Electric Resistance and Packaged DX

Electric

Single Zone, with Electric Resistance and Packaged DX

Single Zone, with Electric Resistance and Water Cooled Chiller

Electric

Single Zone, with Electric Resistance and Water Cooled Chiller

VAV w/ Radiant, with ASHP and Water Cooled Chiller

Electric

VAV w/ Radiant, with ASHP and Water Cooled Chiller

VAV w/ Radiant, with Electric Resistance and Water Cooled Chiller

Electric

VAV w/ Radiant, with Electric Resistance and Water Cooled Chiller

VAV w/ Reheat, with ASHP and Air Cooled Chiller

Electric

VAV w/ Reheat, with ASHP and Air Cooled Chiller

VAV w/ Reheat, with ASHP and Packaged DX

Electric

VAV w/ Reheat, with ASHP and Packaged DX

VAV w/ Reheat, with ASHP and Water Cooled Chiller

Electric

VAV w/ Reheat, with ASHP and Water Cooled Chiller

VAV w/ Reheat, with Electric Boiler and Air Cooled Chiller

Electric

VAV w/ Reheat, with Electric Boiler and Air Cooled Chiller

VAV w/ Reheat, with Electric Boiler and Packaged DX

Electric

VAV w/ Reheat, with Electric Boiler and Packaged DX

VAV w/ Reheat, with Electric Boiler and Water Cooled Chiller

Electric

VAV w/ Reheat, with Electric Boiler and Water Cooled Chiller

VAV w/ Reheat, with Electric Resistance and Air Cooled Chiller

Electric

VAV w/ Reheat, with Electric Resistance and Air Cooled Chiller

VAV w/ Reheat, with Electric Resistance and Packaged DX

Electric

VAV w/ Reheat, with Electric Resistance and Packaged DX

VAV w/ Reheat, with Electric Resistance and Water Cooled Chiller

Electric

VAV w/ Reheat, with Electric Resistance and Water Cooled Chiller

VAV w/ Reheat, with GSHP

Electric

VAV w/ Reheat, with GSHP

Single Zone, with Air Source Heat Pump

Electric

Single Zone, with Air Source Heat Pump

Single Zone, with Ground Source Heat Pump

Electric

Single Zone, with Ground Source Heat Pump

No Mechanical System

No Mechanical System

Did this answer your question?